Changzhou Shuangri Electron Co., Ltd.
Main products:Solar controller, Solar station
Products
Contact Us
  • Contact Person : Mr. wu peter
  • Company Name : Changzhou Shuangri Electron Co., Ltd.
  • Tel : 86-0519-88791737
  • Fax : 86-0519-88522737
  • Address : Jiangsu,changzhou,Chuangxin Road,LuoYang Industry Area,Wujin Zone,ChangZhou,JiangSu,China
  • Country/Region : China
  • Zip : 213104

Offer Solar controller SR1028

Offer Solar controller SR1028
Product Detailed
1.Solar Water system controller for solar water heater 2.OUTDOOR USE 3.TOUCH SCREEN 4.AUSTRALIA,NEW ZEALAND EXCLUSIVELY

 System description Note: T3 is alternative sensor, when no sensor (T3) is installed in the top part of tank, controller will use the signal of sensor T2 automatically to control the auxiliary heating or the circulation pump. 1 collector array – 1 storage tank – 1 pump and auxiliary heating Description: The solar circuit pump (P1) is switched on as soon as the switch-on temperature difference (delt Ton) between the collector array (T1) and the storage tank (T2) is reached. If the temperature difference between the collector array (T1) and storage tank (T2) drops below the switch-off temperature difference (delt Toff), or the temperature of storage tank (T3) reaches the preset maximum storage temperature, then the solar circuit pump ( P1) is switched off. Back-up heating by auxiliary boiler (detailed see paragraph 4.3): Within the preset time section of back-up heating, if the temperature T3 is below the switch-on temperature, then the circulation pump ( H1) of back-up heating is triggered, when T3 is heated to the switch-off temperature, circulation pump H1 of back-up heating is ceased.

4.3  Main  menu  DT  O  &  DT  F  Temperature  difference  function4.4  Main  menu  -  THET  timing  heating4.5  TEMP  Temperature  main  menu4.5.1  EM  Emergency  collector  temperature(Emergency  switch-off  temperature  of  collector)4.5.2  CMX  Maximum  limited  collector  temperature  (collector  cooling  function)4.5.3  CMN  low  temperature  protection  of  collector4.5.4  CFR  frost  protection  of  collector4.5.5  SMX  Maximum  temperature  of  tank4.5.6  REC  Tank  re-cooling  function4.5.7  C-  F  Celsius  and  Fahrenheit  temperature  transferring4.6  HND  Manual  mode4.7  PASS  Password  setting4.8  LOAD  Recovery  factory  setting4.9  Manual  heating4.10  Holiday  function4.11  Temperature  query  function5.  Protection  function5.1.  Memory  protection5.2  Screen  protection6.  Trouble  shooting6.1  Trouble  protection6.2  Trouble  checking


Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.